Smart Antennas

antenne WLAN e Wifi
Features

  • Application: Private Communication
    Product Type: Panel Antenna
    Frequency(MHz): 1000-1600
    Gain(dBi): 14
    Hor.Beamwidth-°: 90
    Polarization: ±45°

    Product model:KDA4-1419D15BT6
    ● 1400~1900MHz
    ● 105°65°
    ● 15dBi 6°Tilt


    pdf
  • Electrical specifications

    KDA4-1419D15BT6

    Frequency range(MHz)

    1400~1525

    1750~1900

    Polarization

    ±45°

    Electrical Downtilt (°)

    6

    Down-tilt Precision(°)

    ±1

    V.S.W.R.

    ≤1.5

    Isolation between Co-polarization Ports(dB)

    ≥28

    Isolation between Cross-polarization Ports(dB)

    ≥28

    Transmission from Any Column’s Port to Calibration Port(dB)

    -26±2

    Max.Altitude Difference between Calibration Port and Each Radiation Port (dB)

    ≤0.7

    Max.Phase Difference between Calibration Port and Each Radiation Port (°)

    ≤5

     

    Single Column

    Horizontal -3dB Beamwidth (°)

    105±15

    65±15

    Gain(dBi)

    ≥14

    Cross Polar Radio (dB)

    ≥18,(±60°≥10)

    Front-to-back Ratio(dB)

    ≥23

    ≥25

     

     

     

    Broadcasting 

    Pattern

    Horizontal Beamwidth(°)

    65±5

    Vertical Beamwidth(°)

    ≥7

    ≥6

    Gain(dBi)

                         ≥15

    Edge level at ±60°(dB)

    12±2

    Cross Polar Radio (dB)

    ≥22,(±60°≥10)

    Front-to-back Ratio(dB)

    ≥28

    First Upper Side Lobe Suppression (dB)

    ≤-15

    First zero level(dB)

    ≥-18

    Traffic Beam Pattern

    Gain for Operation Pattern at 0° Direction (dBi)

    ≥19

    ≥20

    Horizontal Beamwidth for Operation Pattern at 0° Direction (°)

    ≤29

    ≤23

    Horizontal Minor Electric Level for Operation Pattern at 0° Direction (dB)

    ≤-12

    ±60° Direction Gain(dBi)

    ≥18

    Horizontal Beamwidth for Operation Pattern at ±60° Direction (°)

    ≤34

    ≤28

    Horizontal Minor Electric Level for Operation Pattern at ±60° Direction (dB)

    ≤-5

    ≤-4

    Cross Polar Radio for Operation Pattern at 0° Direction (Main-direction)

    ≥22

    Front-to-back Ratio for Operation Pattern at 0° Direction (dB)

    ≥28